HyTEC 2110 - Spinal Cord Dose Tolerance to Stereotactic Body
Radiation Therapy (2019) Category: HyTEC A review of published reports of spinal cord tolerance after stereotactic body radiation therapy was performed. This report presents several dose-response models, recommends dose limits for the spinal cord, and outlines standards for future reporting of spinal cord dosimetric and clinical data. Supplemental Materials 1 International Journal of Radiation Oncology*Biology*Physics https://doi.org/10.1016/j.ijrobp.2019.09.038 Arjun Sahgal, MD, Joe H. Chang, MBChB, PhD, Lijun Ma, PhD, Lawrence B. Marks, MD, Michael T. Milano, MD, PhD, Paul Medin, PhD, Andrzej Niemierko, PhD, Scott G. Soltys, MD, Wolfgang A. Tomé, PhD, C. Shun Wong, MD,* Ellen Yorke, PhD, Jimm Grimm, PhD, and Andrew Jackson, PhD |