The Capability and Characteristic of Helical Tomotherapy at Sparing Hippocampus in Lung Cancer Prophylactic Cranial Irradiation

no image available
J Zhu

J Zhu*, H Li , L Fu , J Gu , T Bai , Y Yin , Shandong Cancer Hospital Affiliated to Shandong University, Jinan, Shandong

Presentations

SU-I-GPD-T-398 (Sunday, July 30, 2017) 3:00 PM - 6:00 PM Room: Exhibit Hall


Purpose: To investigate the capability and characteristic of HT at sparing hippocampus in prophylactic cranial irradiation (PCI).

Methods: Six anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. Under T1-weighted MRI, the hippocampus was contoured, and hippocampal avoidance regions (HAR) were created using a 5-mm volumetric expansion around the hippocampus. The prescription dose 3.0Gy * 10 fractions was assigned on planning target volume (PTV) which was defined as whole-brain minus HAR and bilateral hippocampus. During the HT plan optimization process, evaluation factors of PTV and other dosimetry factors were recorded whenever the mean dose of hippocampus decreased by every 2Gy.

Results: The average of six HT plans without hippocampus sparing constraints are as follow: hippo_Dmean 27.33±2.22Gy, HAR_Dmean 28.62±1.84Gy, PTV_Dmean 30.77±0.74Gy, PTV_D2% 30.93±0.61Gy, PTV_D98% 29.86±0.34Gy, PTV_V30Gy 0.97±0.02% and conformal index (CI) 0.85±0.03, homogeneity index (HI) 0.04±0.01, plan delivery duration 13.70±1.92min.The variation trend of each factors during hippocampus sparing were plotted in figures as follow. When V7.3Gy of bilateral hippocampus achieved 40%, the average dosimetry factors are as follow: hippo_Dmean 8.26±0.24Gy, HAR_Dmean 12.88±1.27Gy, PTV_Dmean 31.00±0.47Gy, PTV_D2% 31.97±0.63Gy, PTV_D98% 21.74±5.44Gy, PTV_V30Gy 0.93±0.02%, CI 0.77±0.08, HI 0.35±0.20, plan delivery duration 21.30±4.97min.

Conclusion: During the process of hippocampus sparing, HAR_Dmean decreased linearly as well. However, dosimetry variation of PTV presented three different regions: plateau region (> 20Gy), gradient region (~20 to ~10Gy) and falling region (<10Gy). There’s almost no significant impact on the PTV dosimetry factors when hippo_Dmean was not lower than 15Gy. With the hippocampus dose decreasing, CI decreased linearly and slightly, however, HI was impaired severely in the falling region. Plan delivery duration time was significantly prolonged during the hippocampus sparing process (from 13min to 23 min).

Funding Support, Disclosures, and Conflict of Interest: This work was supported by the National Natural Science Foundation of China (grant numbers 81671785 and 81530060), the Taishan Scholar Foundation (grant number ts20120505), the China Postdoctoral Science Foundation (grant number 2016T90412) and the Natural Science Foundation of Shandong Province (grant number 2016ZRC03118, ZR2014YL034).