Encrypted login | home

Program Information

Dosimetry Comparison of Advanced External Beam Radiation Treatment Modalities to Brachytherapy Treatments in Patients with Cervical Cancer


S Devic

u mwidu1 , S Devic2*, M Shehadeh3 , M AlKafi4 , R Mahmood5 , B Moftah6 , (1) ,,,(2) McGill University, Montreal, QC, (3) King Faisal Specialist Hospital & Research Center, Riyadh, Riyadh, (4) King Faisal Specialist Hospital & Research Center, Riyadh, Riyadh, (5) King Faisal Specialist Hospital & Research Center, Riyadh, Riyadh, (6) King Faisal Specialist Hospital & Research Center, Riyadh, Riyadh

Presentations

SU-F-T-420 (Sunday, July 31, 2016) 3:00 PM - 6:00 PM Room: Exhibit Hall


Purpose:
A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented.

Methods:
Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended by the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR.

Results:
TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively.

Conclusion:
Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.


Contact Email: