Encrypted login | home

Program Information

Variability of Patient-Specific Motion Models Derived Using Different Deformable Image Registration Algorithms for Lung Cancer Stereotactic Body Radiotherapy (SBRT) Patients


S Dhou

S Dhou1*, D Ionascu2 , J Lewis3 , C Williams4 , (1) Brigham and Women's Hospital / Harvard Medical School, Boston, MA, (2) William Beaumont Hospital, Royal Oak, MI, (3) University of California at Los Angeles, Los Angeles, CA, (4) Brigham and Women's Hospital / Harvard Medical School, Boston, MA

Presentations

SU-C-BRA-7 (Sunday, July 31, 2016) 1:00 PM - 1:55 PM Room: Ballroom A


Purpose: To study the variability of patient-specific motion models derived from 4-dimensional CT (4DCT) images using different deformable image registration (DIR) algorithms for lung cancer stereotactic body radiotherapy (SBRT) patients.

Methods: Motion models are derived by 1) applying DIR between each 4DCT image and a reference image, resulting in a set of displacement vector fields (DVFs), and 2) performing principal component analysis (PCA) on the DVFs, resulting in a motion model (a set of eigenvectors capturing the variations in the DVFs). Three DIR algorithms were used: 1) Demons, 2) Horn-Schunck, and 3) iterative optical flow. The motion models derived were compared using patient 4DCT scans.

Results: Motion models were derived and the variations were evaluated according to three criteria: 1) the average root mean square (RMS) difference which measures the absolute difference between the components of the eigenvectors, 2) the dot product between the eigenvectors which measures the angular difference between the eigenvectors in space, and 3) the Euclidean Model Norm (EMN), which is calculated by summing the dot products of an eigenvector with the first three eigenvectors from the reference motion model in quadrature. EMN measures how well an eigenvector can be reconstructed using another motion model derived using a different DIR algorithm. Results showed that comparing to a reference motion model (derived using the Demons algorithm), the eigenvectors of the motion model derived using the iterative optical flow algorithm has smaller RMS, larger dot product, and larger EMN values than those of the motion model derived using Horn-Schunck algorithm.

Conclusion: The study showed that motion models vary depending on which DIR algorithms were used to derive them. The choice of a DIR algorithm may affect the accuracy of the resulting model, and it is important to assess the suitability of the algorithm chosen for a particular application.

Funding Support, Disclosures, and Conflict of Interest: This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.


Contact Email: