Program Information
Monte Carlo Evaluation of Kilovoltage Radiosurgery with AuNPs for Age Related Macular Degeneration (AMD)
D Brivio1*, P Zygmanski2 , E Sajo3 , G Makrigiorgos4 , W Ngwa5 , (1) ,,,(2) Brigham & Women's Hospital, Boston, MA, (3) Univ Massachusetts Lowell, Lowell, MA, (4) Dana Farber Cancer Institute, Boston, MA, (5) Harvard Medical School, Boston, MA
Presentations
TU-G-CAMPUS-T-12 (Tuesday, July 14, 2015) 5:30 PM - 6:00 PM Room: Exhibit Hall
Purpose: To evaluate the benefit of gold nanoparticles (AuNP) in radiosurgery of Age related Macular Degeneration (AMD) using Monte Carlo (MC) simulation. AMD disease causes vision loss due to a leaky vasculature of the endothelial cells. Radiosurgical therapy aims to destroy this vasculature while minimizing the delivered dose to healthy tissues of the eye. AuNP known to enhance local dose have been targeted to the macular choroidal endothelial cells to increase the therapeutic efficacy.
Methods: Dose enhancement ratio (DER) in macula endothelial cells due to a thin layer of AuNP has been calculated by a MC radiation transport simulation. AuNP layer (10-100nm) has been placed on the bottom of the macula at 2.4cm depth in a water parallelepiped 3x3x6cm3. This layer has been modeled considering various concentrations of AuNP ranging from 5.5-200mg per gram of endothelial cell (volume 10x10x2um3). The x-ray source is 100kVp 4mm diameter beam tilted 0°-30° with respect to the lens.
Results: DER in endothelial cell for AuNP concentration of 31mg/g (shown experimentally feasible) and 10-100nm sizes is about 1.8. Tilting 4mm-beam does not reduce the enhancement but allows to avoid the surrounding tissues. Dose distribution in the AuNP vicinity has a significant increase within 30um, peaked at AuNP interface. DER inside and outside of the irradiation 4mm-field are the same while the actual delivered dose is more than one order of magnitude lower outside the field. Compared to 100kVp, usage of filtered spectra with enhanced flux in the region 20keV-40keV shows further increase of DER by about 20%. Dose to the neighboring organs such as retina/optic nerve are reduced accordingly.
Conclusion: The results of this MC simulation provide further confirmation of the potential to enhance DER with AuNP from previous analytical calculations. This study provides impetus to improve treatment effectiveness of AMD disease with radiotherapy.
Contact Email: