CBCT Based Rectum and Bladder Dose Tracking in the Prostate Radiotherapy


W Hu

Z Chen , J Wang , Z Yang , W Hu*, Fudan university shanghai cancer center, Shanghai, China

Presentations

SU-E-J-83 (Sunday, July 12, 2015) 3:00 PM - 6:00 PM Room: Exhibit Hall


Purpose:The aim of this study is to monitor the volume changes of bladder and rectum and evaluate the dosimetric changes of bladder and rectum using daily cone-beam CT for prostate radiotherapy.
Methods:The data of this study were obtained from 12 patients, totally 222 CBCTs. All the volume of the bladder and the rectum on the CBCT were normalized to the bladder and the rectum on their own original CT to monitory the volume changes. To evaluate dose delivered to the OARs, volumes that receive 70Gy (V70Gy), 60Gy, 50Gy, 40Gy and 30Gy are calculated for the bladder and the rectum, V20Gy and V10Gy for rectum additionally. And the deviation of the mean dose to the bladder and the rectum are also chosen as the evaluation parameter. Linear regression analysis was performed to identify the mean dose change of the volume change using SPSS 19.
Results:The results show that the variances of the normalize volume of the bladder and the rectum are 0.15-0.58 and 0.13-0.50. The variances of V70Gy, V60Gy, V50Gy, V40Gy and V30Gy of bladder are bigger than rectum for 11 patients. The linear regression analysis indicated a negative correlation between the volume and the mean dose of the bladder (p < 0.05). A 10% increase in bladder volume will cause 5.1% (±4.3%) reduction in mean dose.
Conclusion:The bladder volume change is more significant than that for rectum for the prostate cancer patient. The volume changes of rectum are not significant except air gap in the rectum. Bladder volume varies will cause significant dose change. The bladder volume monitoring before fractional treatment delivery would be crucial for accuracy dose delivery.