Purpose:
SBRT allows the delivery of high dose radiation treatments to localized tumors while minimizing dose to surrounding tissues. Due to the large doses delivered, accurate contouring of organs at risk is essential. In this study, differences between the true spinal cord as seen using MRI and CT myelogram (CTM) have been assessed in patients with spinal metastases treated using SBRT.

Methods:
Ten patients were identified that have both a CTM and a MRI. Using rigid registration tools, the MRI was fused to the CTM. The thecal sac and true cord were contoured using each imaging modality. Images were exported and analyzed for similarity by computing the Dice similarity coefficient and the modified Hausdorff distance (greatest distance from a point in one set to the closest point in the other set).

Results:
The Dice coefficient was calculated for the thecal sac (0.81 ±0.06) and true cord (0.63 ±0.13). These two measures are correlated; however, some points show a low true cord overlap despite a high overlap for the thecal sac.
The Hausdorff distance for structure comparisons was also calculated. For thecal sac structures, the average value, 1.6mm (±1.1), indicates good overlap. For true cord comparison, the average value, 0.3mm (±0.16), indicates very good overlap. The minimum Hausdorff distance between the true cord and thecal sac was on average 1.6mm (±0.9).

Conclusion:
The true cord position as seen in MRI and CTM is fairly constant, although care should be taken as large differences can be seen in individual patients.. Avoidning the true cord in spine SBRT is critical, so the ability to visualize the true cord before performing SBRT to the vertebrae is essential. Here, CT myelogram appears an excellent, robust option, that can be obtained the day of treatment planning and is unaffected by uncertainties in image fusion.