Encrypted login | home

Program Information

Dosimetric Properties of a New Solid Water High Equivalency Phantom for High-Energy Photon Beams


F Araki

F Araki1*, T Ohno1 , R Onitsuka1 , Y Shimohigashi2 , (1) Kumamoto University, Kumamoto, (2) Kumamoto University Hospital, Kumamoto

Presentations

SU-E-T-336 (Sunday, July 12, 2015) 3:00 PM - 6:00 PM Room: Exhibit Hall


Purpose: To investigate dosimetric properties in high-energy photon beams for a Solid Water High Equivalency (SWHE, SW557) phantom (Gammex) which was newly developed as water mimicking material.

Methods: The mass density of SWHE and SWHE/water electron density ratio are 1.032 g/cm³ and 1.005 according to the manufacturer information, respectively. SWHE is more water equivalent material in physical characteristics and uniformity than conventional SW457. This study calculated the relative ionization ratio of water and SWHE as a function of depth from the cavity dose in PTW30013 and Exradin A19 Farmer-type ionization chambers using Monte Caro simulations. The simulation was performed with a 10 x 10 cm² field at SAD of 100 cm for 4, 6, 10, 15, and 18 MV photons. The ionization ratio was also measured with the PTW30013 chamber for 6 and 15 MV photons. In addition, the overall perturbation factor of both chambers was calculated for both phantoms.

Results: The relative ionization ratio curves for water and SWHE was in good agreement for all photon energies. The ionization ratio of water/SWHE for both chambers was 0.999-1.002, 0.999-1.002, 1.001-1.004, 1.004-1.007, and 1.006-1.010 at depths of over the buildup region for 4, 6, 10, 15, and 18 MV photons, respectively. The ionization ratio of water/SWHE increased up to 1% with increasing the photon energy. The measured ionization ratio of water/SWHE for 6 and 15 MV photons agreed well with calculated values. The overall perturbation factor for both chambers was 0.983-0.988 and 0.978-0.983 for water and SWHE, respectively, in a range from 4 MV to 18 MV.

Conclusion: The depth scaling factor of water/SWHE was equal to unity for all photon energies. The ionization ratio of water/SWHE at a reference depth was equal to unity for 4 and 6 MV and larger up to 0.7% than unity for 18 MV.


Contact Email: