Encrypted login | home

Program Information

Clinical Evaluation of VirtualDose - a Software for Tracking and Reporting CTDI, DLP, Organ and Effective Dose for Adult and Pediatric Patient

no image available
A Ding

A Ding1*, Y Gao1, P Caracappa1, D Long2, W Bolch2, B Liu3, M Kalra,3, X Xu1, (1) Rensselaer Polytechnic Institute, Troy, NY, (2) University of Florida, Gainesville, Florida, (3) Massachusetts General Hospital, Boston, MA

TU-G-103-2 Tuesday 4:30PM - 6:00PM Room: 103

Purpose:

To update the development and clinical testing of a new Software as a Service (SaaS) -VirtualDose for tracking and reporting CT doses.
Methods:
Incorporating SaaS technology and the comprehensive original dose data derived from Monte Carlo simulations on a family of adult and pediatric computational phantoms, covering 50th-percentile adults and children at different ages, pregnant females at three gestational stages, and a set of overweight and obese phantoms, VirtualDose is being designed as a Web based CT dose reporting platform. For the client- and server-side scripting, JavaScript, Hypertext Markup Language, Cascading Style Sheets, and C# were used. A JSON (JavaScript Object Notation) is used as a request-response interaction pattern to connect both the client- and server-side. Organ doses and effective doses are computed using ICRP Publication 60 and 103. Patient-specific dosimetry capabilities are included by integrating a DICOM reader function module which could automatically extract dose, patient, and CT scanner (e.g., CTDI, DLP, kVp, mAs, weight, age, gender, etc.) information.

Results:
VirtualDose has been developed as a CT dose reporting SaaS by offering a web-based dynamic user-friendly interface. Based on the user-specified scanning parameters, VirtualDose rapidly report the organ dose data from the remote server-side database and interactively tabulate and plot the results of interest within a web browser. Clinical testing found the dose up to 24% different as compared to those derived from the stylized MIRD-type phantoms. The morbidly obese phantom received up to 60% smaller CT dose than that of the normal weight phantom

Conclusion:
VirtualDose is now available in the following website: http://www.virtualphantoms.com and being tested at more than 20 medical centers nationwide. Using a large library of adult and pediatric phantoms, it provides more accurate dose data and is expected to improve both the accuracy and usability in CT dose reporting in the future.

Contact Email: