Program Information
Detection of Articular Knee Cartilage Defects Using PD BLADE with Fat Saturation (FS), PD FS and T2 3D DESS with Water Excitation (WE)
P Mavroidis1,2*, E Lavdas3, T Topalzikis4, I Kyriakis4, V Roka5, S Kostopoulos3, D Glotsos3, K Zilidis6, S Stathakis1, A Tsagkalis4, N Papanikolaou1, K Vassiou6, G Batsikas4, (1) University of Texas Health Science Center, UTHSCSA, San Antonio, TX, (2) Karolinska Institutet and Stockholm University, Stockholm, Sweden, (3) Techological Education Institute of Athens, Athens, Greece,(4) IASO Thessalias Hospital, Larissa, Greece,(5) Health Center of Farkadona, Trikala, Greece,(6) University Hospital of Larissa, Larissa, Greece
SU-E-I-71 Sunday 3:00PM - 6:00PM Room: Exhibit HallPurpose: The purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5mm slice thickness, both derived from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG) sequence, regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations.
Methods: Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56 years, range 37-71 years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated.
Results: The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p<0.001). The sequences T2 3D DESS 1.5mm and T2 3D DESS 3mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone, Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. Also, in the PD BLADE FS COR sequence, the results of the Truncation Artifact, Pulsation Artifact, Edge Sharpness and Blurring Artifacts, were superior to the other sequences (p<0.001).
Conclusion: PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and T2 3D DESS sequences.
Contact Email: