Report
307
TG307 |
 |
2023
AAPM Task Group Report 307: Use of EPIDs for Patient-Specific IMRT and VMAT QA 'QA' found in Title, Summary, Committee/Notes |
Report
306
TG306 |
 |
2023
AAPM Task Group Report 306: Quality control and assurance for tomotherapy: An update to Task Group Report 148 'QA' found in Summary, Committee/Notes |
Report
303
TG303 |
 |
2022
AAPM task group report 303 endorsed by the ABS: MRI implementation in HDR brachytherapy—Considerations from simulation to treatment 'QA' found in Summary |
Report
302
TG302 |
 |
2022
AAPM task group report 302: Surface guided radiotherapy 'QA' found in Summary |
Report
262
TG262 |
 |
2021
Electronic Charting of Radiation Therapy Planning and Treatment: Report of Task Group 262 'QA' found in Summary |
Report
219
TG219 |
 |
2021
Report of AAPM Task Group 219 on independent calculation-based dose/MU verification for IMRT 'QA' found in Summary |
Report
198
TG198 |
 |
2021
AAPM Task Group 198 Report: An Implementation Guide for TG 142 Quality Assurance of Medical Accelerators 'QA' found in Summary, Committee/Notes, Keywords |
Report
201.A
TG201 |
 |
2021
Report of Task Group 201 of the American Association of Physicists in Medicine: Quality Management of External Beam Therapy Data Transfer 'QA' found in Summary |
Report
178
TG178 |
 |
2021
Recommendations on the Practice of Calibration, Dosimetry, and Quality Assurance for Gamma Stereotactic Radiosurgery: Report of AAPM Task Group 178 'QA' found in Summary |
Report
284
TG284 |
 |
2021
AAPM Task Group 284: Magnetic Resonance Imaging Simulation in Radiotherapy: Considerations for Clinical Implementation, Optimization, and Quality Assurance 'QA' found in Summary |
Report
235
TG235 |
 |
2020
Report of AAPM Task Group 235 - Radiochromic Film Dosimetry: An update to TG-55 'QA' found in Summary |
Report
270.A
TG270 |
 |
2020
Practical application of AAPM Report 270 in display quality assurance: A report of Task Group 270 'QA' found in Committee/Notes |
Report
126
TG126 |
 |
2019
PET/CT Acceptance Testing and Quality Assurance 'QA' found in Summary |
Report
224
TG224 |
 |
2019
AAPM task group 224: comprehensive proton therapy machine quality assurance 'QA' found in Summary, Committee/Notes, Keywords |
Report
270
TG270 |
 |
2019
Display Quality Assurance 'QA' found in Summary, Keywords |
Report
218
TG218 |
 |
2018
Tolerance Limits and Methodologies for IMRT Measurement-Based Verification QA: Recommendations of AAPM Task Group No. 218 'QA' found in Title, Summary, Committee/Notes |
Report
211
TG211 |
 |
2017
Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211 'QA' found in People |
Report
175
TG175 |
 |
2016
Acceptance Testing and Quality Control
of Dental Imaging Equipment 'QA' found in Keywords |
Report
118
TG118 |
 |
2015
Parallel Imaging in MRI: Technology, Applications, and Quality Control 'QA' found in Summary |
Report
166
TG166 |
 |
2012
The Use and QA of Biologically Related Models for Treatment Planning 'QA' found in Title, Summary |
Report
154
TG154 |
 |
2011
Quality assurance of U.S.-guided external beam radiotherapy for prostate cancer: Report of AAPM Task Group 154 'QA' found in Summary |
Report
135
TG135 |
 |
2011
Report of AAPM TG 135: Quality assurance for robotic radiosurgery 'QA' found in Summary |
Report
120
TG120 |
 |
2011
Dosimetry tools and techniques for IMRT 'QA' found in Summary |
Report
148
TG148 |
 |
2010
QA for helical tomotherapy: Report of the AAPM Task Group 148 'QA' found in Title, Summary |
Report
101
TG101 |
 |
2010
Stereotactic body radiation therapy: The report of AAPM Task Group 101 'QA' found in Summary |
Report
142
TG142 |
 |
2009
Task Group 142 report: Quality assurance of medical accelerators 'QA' found in Summary, Committee/Notes |
Report
119
TG119 |
 |
2009
IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119 'QA' found in Committee/Notes |
Report
116
TG116 |
 |
2009
An Exposure Indicator for Digital Radiography 'QA' found in Summary |
Report
097
TG074 |
 |
2009
Report of AAPM Therapy Physics Committee Task Group 74: In-air output ratio, Sc, for megavoltage photon beams 'QA' found in Summary |
Report
091
TG076 |
 |
2006
The Management of Respiratory Motion in Radiation Oncology 'QA' found in Summary |
Report
271
TG068 |
 |
2005
Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68 'QA' found in Summary |
Report
086
QA |
 |
2004
Quality Assurance for Clinical Trials: A Primer for Physicists 'QA' found in Summary, Committee/Notes |
Report
074
TG012 |
 |
2002
Quality Control in Diagnostic Radiology ** RETIRED **
'QA' found in Summary |
Report
073
TG006 |
 |
2001
Medical Lasers: Quality Control, Safety Standards, and Regulations 'QA' found in Summary |
Report
072
TG050 |
 |
2001
Basic Applications of Multileaf Collimators 'QA' found in Summary |
Report
065
TG001 |
 |
1998
Real-Time B-Mode Ultrasound Quality Control Test Procedures 'QA' found in Summary |
Report
062
TG053 |
 |
1998
American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planning 'QA' found in Summary |
Report
061
TG059 |
 |
1998
High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group No. 59 'QA' found in Summary |
Report
046
TG040 |
 |
1994
Comprehensive QA for Radiation Oncology 'QA' found in Title, Summary, Committee/Notes |
AAPM Reports are based on sources and information believed to be reliable, but AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. AAPM does not endorse any products, manufacturers, or suppliers. Nothing in these publications should be interpreted as implying such endorsement.